portfolio_page-template-default,single,single-portfolio_page,postid-22348,qode-social-login-1.0,qode-restaurant-1.0,stockholm-core-2.0.2,select-child-theme-ver-3.8.1,select-theme-ver-3.8.1,ajax_fade,page_not_loaded,menu-animation-underline-bottom,,qode_menu_,wpb-js-composer js-comp-ver-6.4.1,vc_responsive,elementor-default,elementor-kit-22393

RE80

Technical Data:
Power Supply: 3×400/50Hz (Other voltages/Hz on request)
Power consumption: 24 kW
Max. current: 41 Amps
Operation current: 28 Amps (Required start-up Amps should be calculated as 5 to 6 times Amp usage.)
Power connection: 63A/3P+E
Dimensions (WxDxH): 1320x1960x1570 mm
Weight: 1070 kg
Max ambient temperature: 40°C
Max. hose length between PE80 and RE80: 6m.
Airflow: Approximately 8500m3/h
Total heat rejection: 18 kW
Protection against recycling discharge air required
Protection against direct sun, rain and snow
Protection against dust, dirt and impurities
LCO2 to dry ice conversion with recovery unit: 1.2:1 (use insulated cover on dry ice box)
Oil type: Castrol Cygnus PAO 68
CO2 monitoring

 

Cooling System:
Bitzer LH104/4TCS8.2Y
Refrigerant type R404A
Refrigerant charge approx. 9.9 kg
High and low pressure protection
Fanspeed control (1 fan)
Refrigerant safety valve