Technical Data: |
|
Power Supply: |
3×400/50Hz (Other voltages/Hz on request) |
Power consumption: |
24 kW |
Max. current: |
41 Amps |
Operation current: |
28 Amps (Required start-up Amps should be calculated as 5 to 6 times Amp usage.) |
Power connection: |
63A/3P+E |
Dimensions (WxDxH): |
1320x1960x1570 mm |
Weight: |
1070 kg |
Max ambient temperature: |
40°C |
Max. hose length between PE80 and RE80: |
6m. |
Airflow: |
Approximately 8500m3/h |
Total heat rejection: |
18 kW |
Protection against recycling discharge air required |
Protection against direct sun, rain and snow |
Protection against dust, dirt and impurities |
LCO2 to dry ice conversion with recovery unit: 1.2:1 (use insulated cover on dry ice box) |
Oil type: Castrol Cygnus PAO 68 |
CO2 monitoring |
Cooling System: |
|
Bitzer LH104/4TCS8.2Y |
Refrigerant type R404A |
Refrigerant charge approx. 9.9 kg |
High and low pressure protection |
Fanspeed control (1 fan) |
Refrigerant safety valve |
Category